Skip to content

Specification

Parameter Value
Principle Through-beam photocell (transmitter + receiver), infrared beam
Sensors Industrial SICK G10 series
Proven range About 10 m in direct sunlight on an outdoor velodrome
Beam height Low above the surface, set to the track geometry
Aiming Fine adjustment on the transmitter side, inside the housing
Housings Custom 3D-printed housings designed for outdoor use
Parameter Value
Timestamp Taken at the gate, microsecond resolution
Gate sync The tower server is the time source for all gates
Target accuracy ±0.01 s (validation in progress)
Gates 2 to 7 per track
Parameter Value
Gate link UTP Ethernet to the tower
Gate power 230 V at the gate (pilot version)
Server Local computer in the tower, works without internet
Parameter Value
Rider Web app on the phone, nothing to install
Display Any TV with a browser
Efforts Flying 200 m, flying lap, standing starts, pursuits with splits, free riding
Data Session history, personal bests, CSV export for coaches
Status In development